/Under the NSW ENVIRONMENTAL PLANNING AND ASSESSMENT REGULATION 2000, in the case of a class 1 and/or 10 building, the inspections that are to be carried out by the Principal Certifier [PC] are currently [with applicability as determined by the PC] :
after the barrier has been erected before filling pool with water, and
after excavation for, and prior to the placement of, any footings, and
prior to pouring any in-situ reinforced concrete building element, and
prior to covering of the framework for any floor, wall, roof or other building element, and
prior to covering waterproofing in any wet areas, and
prior to covering any stormwater drainage connections, and
After the building work has been completed and prior to any occupation certificate being issued in relation to the building (EPA REGS 2000).